HD2

HD2 underwent a renovation in 2023 and today has a full IP infrastructure based on ST-2110, controlled by NEP's own control system TFC. It has an audio control room that can meet all requirements for large-scale sporting events and the production of large entertainment shows. With space for up to 24 cameras, four CCU operators, six slow-motion operators and two separate production units, the HD2 meets the requirements for the most extensive productions. The HD2 has its own custom-built semitrailer that serves as a storage and transport vehicle for all peripheral equipment used for a major sports production or other large-scale event.

No items found.

What’s a Rich Text element?

The rich text element allows you to create and format headings, paragraphs, blockquotes, images, and video all in one place instead of having to add and format them individually. Just double-click and easily create content.

Static and dynamic content editing

A rich text element can be used with static or dynamic content. For static content, just drop it into any page and begin editing. For dynamic content, add a rich text field to any collection and then connect a rich text element to that field in the settings panel. Voila!

How to customize formatting for each rich text
  • Headings, paragraphs, blockquotes, figures, images, and figure captions can all be styled after a class is added to the rich text element using the "When inside of" nested selector system.
  • ‍Headings, paragraphs, blockquotes, figures, images, and figure captions can all be styled after a class is added to the rich text element using the "When inside of" nested selector system.

Headings, paragraphs, blockquotes, figures, images, and figure captions can all be styled after a class is added to the rich text element using the "When inside of" nested selector system.

UPS:

  • All technical equipment is protected by UPS (3x 11kVA)

VIDEO MIXER

  • Sony XVS-8000,HD 720p50/1080i50/1080p50
  • 4 splitable M/E cards, each with 8 keyers
  • 64 Inputs, 32 Outputs
  • 8 channels frame/clip memory
  • Integrated 4-ch DME, resizer on all keyers
  • 8 Format Converters
  • Separate mixer panel with full M/E for sub production

GRAPHICS/CG

  • VizRT Engine and Laptop with VizRT Trio and Artist

MONITORING

  • Production: 6x 55” multiviewers
  • 2nd Production: 2 x 47” multiviewers
  • 5 x EVS positions with multiviewer
  • 3 x CCU positions with multiviewer and OLED monitor
  • EiC position with multiviewer and OLED monitor
  • Audio: 1 x42” multiviewer and 2 OLED monitors w/low latency 

VIDEO

  • LAWO C100based ST-2110 based video/audio with DMV Multiviewer system
  • 3 x Lawo Vpro8 w/X-converters 

CONTROL SYSTEM

  • Routerpanels: TFC iPads / LAWO router panels
  • Tally/UMD system: NEP TFC Control system

EVS / TAPE MACHINES / USB RECORDERS

  • Up to 4 x 12-CHEVS
  • Up to 4 x XDCamHD/HDCam recorder/players
  • Recording toup to 8x USB sticks

CAMERAS

  • 12 x GV LDX86
  • Wired for 24 x CCUsSONY/GV
  • Wired for 2 x VislinkWireless CCUs
  • Lemo SMPTE 311 Fiber Cables

TRIPODS

  • Vinten2-stage ENG-tripods (Vinten 100/250)

LENSES:

  • CanonHJ22x7,6
  • All other lenses available upon request

AUDIO

  • Lawo MC2 56HD MKII w/48 faders digital mixer/audio routing matrix
    • Redundant 8192x8192 Router cards
    • 5 DSP cards
    • 8 Ravenna ports
    • 16 MADI ports
    • 16 local mic in, 16 analog line out, 8 AES/EBU i/o
    • Stageboxes on request
  • Monitoring:5.1 set-up, Genelc 8240 series + Sub.
  • ProTools HD2mac-setup for 64 ch recording.
  • Mac mini for jingles/bumpers etc.
  • Dolby Eencoder/decoder/audio-tool
  • TC Electronics M3000 + 4000 + 6000 + 2 x D-Two

• MICROPHONES

  • SennheiserMKH 70 / MKH 416 / MKH 40 / Handheld

COMMUNICATION

  • Matrix:Riedel Artist 128
    • Ready for 44 panels / 48x analogue 4w / 12xAES/EBU 4w
    • 4 external panels/Desk-top panels
    • 1 Commentator panel
  • VOIP and GSM codecs
  • 3 x duplex base stations for wireless communication
  • 12 xPortable radios 

TRUCK:

DIMENSIONS:

  • Total length: 18 meters
  • Total width: 2,5 meters, expanded for production: 4,3 meters
  • Height: 4 meters
  • Total weight: 29 tons
  • Space required to park the OB-truck andtender vehicle: 41 x 5 meters or 20 x 10 meters 

POWER REQUIREMENTS:

  • 1 x 63A, 3-phase, 400V or 2 x 63A,3-phase 230V
  • Powercable carried on vehicle: 2 x 40 meters

 

HD2 Floorplan